Properly sizing a tankless water heater requires evaluating a home’s hot water demand to ensure the system can meet household needs and deliver sufficient hot water.

Fixture usage: Consider how many fixtures are likely to operate simultaneously, rather than sizing the unit solely on the total number of bathrooms. For example, a 10-bathroom home with only two occupants may not require a system capable of supplying hot water to all 10 bathrooms at the same time.

Incoming water temperature: Account for the temperature rise required to heat the incoming groundwater to the desired hot-water temperature.

Seasonal temperature changes: Consider the coldest expected groundwater temperatures in winter, particularly in colder climates like New England and the Midwest, rather than basing sizing decisions on installation-time temperatures.

Existing equipment capacity: Avoid replacing an undersized tank water heater with a similarly sized tankless unit without reevaluating the home’s actual hot water needs.

Here’s what you should consider when it comes to gas supply, combustion air and venting.

Gas line sizing and pressure: Verify the pipe diameter. Gas piping is an important consideration when installing a tankless water heater, particularly when replacing a traditional tank-style unit. Traditional tank water heaters commonly use 1/2-inch gas lines; tankless units typically require at least 3/4-inch piping.

Plumbers should evaluate the diameter and length of the existing gas line to determine whether it needs to be upsized. A larger pipe diameter and shorter gas line allow more gas to reach the unit.

Verify gas pressure. Both static and dynamic gas pressure should be checked to confirm the unit receives an adequate gas supply. Static pressure measures the gas pressure when the heater is not operating, while dynamic pressure measures the pressure when the heater is running. The recommended pressure ranges are 3.5 to 10.5 inches of water column for natural gas; 8 to 14 inches of water column for propane.

The heater should also be tested under high-demand conditions by running multiple fixtures simultaneously. While operating a single faucet may not reveal gas supply issues, running a bathtub or multiple fixtures increases demand and can cause gas pressure to drop if the piping cannot supply enough gas. Testing under these conditions helps identify potential gas supply limitations before completing the installation.

Combustion air and venting: Plumbers should check that a residential tankless water heater has access to an adequate supply of clean, fresh combustion air. For example, if a unit is installed in a closet, the space will need sufficient airflow through louvers or other openings.

The quality of the intake air is equally important. A garage used for woodworking may expose the heater to sawdust, which can be pulled into the unit and cause clogs. In this situation, drawing fresh air from outside may be preferable.

Verify combustion air. Plumbers should follow manufacturer installation instructions and applicable local codes when determining intake placement. Local codes may specify how far intake openings must be from corners, eaves, and other exhaust outlets. For installations that draw combustion air from inside the room, provide at least 1 square inch of fresh air for every 1,000 BTUs being burned. For example, a 200,000 BTU water heater requires at least 200 square inches of fresh air.

Check the air-to-gas ratio. The proper air-to-gas ratio is necessary for the heater to fire correctly. Units factory-set for natural gas may require adjustments when converted to propane to accommodate the different gas type. An improper air-to-gas mixture can cause combustion issues, including error codes, sputtering, or unusual noises when the heater fires up.

When should a tankless water heater be descaled?

Water quality and routine maintenance play important roles in maintaining the performance of tankless water heaters over time. As water is heated at high temperatures, minerals can precipitate and accumulate inside the heat exchanger and internal piping. This scale buildup can restrict water flow, contribute to clogs, and cause leaks over time.

Installing a water filtration system can help protect the unit. This filtration does not necessarily require a whole-house system, as smaller, affordable options are also available.

Descaling frequency depends on the home’s water quality and hot water usage. For water with a hardness of up to 3 grains per gallon, descaling is technically not required. When water hardness exceeds 3 grains per gallon, and no filtration is installed, the unit should be descaled at least once a year. Filtration may extend that interval by approximately one year.

Plumbers should also include filter replacement as part of routine maintenance, with filters replaced approximately every two years.

Final checks before completing installation

Revisit sizing calculations to confirm the selected unit can meet the household’s hot water demand.

Confirm the gas line capacity to ensure it can supply the unit’s required BTUs.

Check the installation location and fresh-air supply to ensure the heater has access to clean, adequate air.

Test each faucet and shower individually post-installation to confirm that hot water reaches each fitting.

Identify potential plumbing issues that may become more noticeable when switching from a traditional tank water heater to a tankless system, as the previous equipment may have masked minor problems.


About the Author

Jared Mead is a product trainer at Noritz America. Contact him at 